HEAS Series ABS Electric Actuator
HEAS Series ABS Electric Actuator
HEAS Series ABS  Electric Actuator
HEAS Series ABS  Electric Actuator
HEAS Series ABS  Electric Actuator
HEAS Series ABS  Electric Actuator
HEAS Series ABS Electric Actuator
HEAS Series ABS Electric Actuator
HEAS Series ABS Electric Actuator
HEAS Series ABS Electric Actuator

HEAS ABS Quarter-Turn Electric Actuator is used for controlling 0~90 degree rotation valves and other similar products, such as butterfly valve,ball valve,damper,flapper valve,cock valve etc.

Description

HEAS Series Quarter-Turn Electric Actuator is used for controlling 0~90 degree rotation valves and other similar products,such as butterfly valve,ball valve,damper,flapper valve,cock valve etc...It widely applies to petroleum,chemical,water treament,shipping,peper,making,power plant and other industries.Drived by 380V/220V/110VAC or 24V/110VDC Power.

 

Technical Parameter

HEAS003

HEAS005

HEAS005

HEAS010

HEAS015

 

Model

Torque (N·m)

Voltage (220VAC)

Voltage (24VDC)

Power (W)

Current (A)

Open/Close Time (S)

Power (W)

Current (A)

Open/Close Time (S)

HEAS003

30

6

0.18

15

6

0.5

15

HEAS005

50

6

0.18

31

6

0.5

13

HEAS010

100

15

0.35

28

15

3

7

HEAS015

150

20

0.4

28

20

4

7

 

Adjustment of Limit Switch (electrical limit)

1、Use the handle to drive the valve to the fully open position,loosen the nut for oneturn,turn the D2 yellow limit block anticlockwise to make it just to the switch limit,and after hearing "dada" twice,the opening is complete.

2、Use the handle to drive the valve to the fully closed position,turn the D1red limit block clockwise to make it just touch the switch limit,hear “dada" twice,and then complete the locking nut.

 

Dimensions

 

 

 

Dimension in MM

News

2026

/

30
Sep

Why Does an Electric Actuator Overheat During Operation?

Learn how cycling, valve resistance, electrical conditions and the installa...

2026

/

29
Sep

What Should You Check Before Commissioning a Quarter Turn Pneumatic Actuator?

Check mounting, air supply, valve travel and position feedback before putti...

2026

/

10
Sep

Why Does a Pneumatic Actuator Lose Air Pressure or Leak Air?

Learn why pneumatic actuators lose air pressure, where leaks occur, and wha...

2026

/

04
Sep

What Is an Electric Actuator? The Complete Guide for Industrial Valve Automation

Industrial automation relies on precise motion control to regulate the flow...

GET A QUOTE

Get in Touch

Captcha Code
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All